CUSTOMER SERVICE
자료실

ARMOR AWARD ROHS(Restriction of Hazardous Substances Directive)

ARMOR AWARD ROHS(Restriction of Hazardous Substances Directive)
다운로드 (1)
#카테고리1
Test Report

No. RN14-12698.021-A
Date : 07182014

ARMOR SA
7 RUE DE LA PELISSIERE 44118 LA CHEVROLIERE FRANCE

The following sample(s) was/were submitted and identified by/on behalf of the client as :
SGS Job No. : RN 14-12698.021-A
Item / Item No. : THERMAL TRANSFER RIBBON - AWARD
Buyer : Mme Melanie BLIN
Sample Receiving Date : 06252014
Testing Period : 06252014-07182014

Test Requested : With reference to RoHS Directive 2011/65/UE, and its amendment directives.
Test Method : Please refer to next page(s).
Test Result(s) : Please refer to next page(s).
Conclusion : Based on the performed tests on submitted sample(s), the results are in compliance with the RoHS Directive 2011/65/UE and its subsequent amendments.

Test result :
ID for sample 1 : THERMAL TRANSFER RIBBON
Description for sample 1 : AWARD

RoHS Directive 2011/65/UE

[Test ltem(s) / Unit / Test Method / Results / MQL / Limit]
Cadmium(Cd) / mg/kg / IEC 62321:2008 (Ed.12/2008) with modified digestion procedure, and performed by ICP-OES / <MQL / 2 / 100
Lead(Pb) / mg/kg / IEC 62321:2008 (Ed.12/2008) with modified digestion procedure, and performed by ICP-OES / 5 / 2 / 1000
Mercury (Hg) / mg/kg / IEC 62321:2008 (Ed.12/2008) with modified digestion procedure, and performed by CV-AFS / <MQL / 0.3 / 1000
Hexavalent Chromium (CrVI) / mg/kg / With reference to IEC 62321:2008, and calculated with the result of total Chromium, and performed by ICP-OES / <MQL / 2 / 1000
Sum of PBBs / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 255 / 1000
Monobromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Dibromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Tribromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Tetrabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Pentabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Hexabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
SUM of Heptabromobiphenyl, Octabromobiphenyl and Nonabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 125
Decabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 125 / -
Sum of PBDEs / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 535 / 1000-
Monobromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Dibromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5
Tribromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Tetrabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Pentabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Hexabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Heptabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Octabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL 125 / -
Nonabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL 125 / -
Decabromodiphenyl ether ## / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 250 / -

Note :
(a) mg/kg = ppm ; 0.1 wt% = lOOOppm
(b) n.d. = not detected, than less than le limit of quantification
(c) MQL = Method Quantification Limit
(d) - = not regulated
hion hion · 2019-06-13 13:33 · 조회 4297
Instagram

This error message is only visible to WordPress admins

Error: API requests are being delayed for this account. New posts will not be retrieved.

There may be an issue with the Instagram Access Token that you are using. Your server might also be unable to connect to Instagram at this time.

Contact

Add. 서울시 금천구 가산디지털 2로 165
백상스타타워 2차 1304호 
Tel. 02. 2038. 0018
Fax. 02. 2038. 0058
Email. hion@hionit.com

Link

하이온 공식 블로그

하이온 몰

하이온 유튜브